Central Wavelength 1550nm; Output Power 20mW; Narrow Linewidth < 100KHz; Tolerance ±1nm; SMF-28 fiber; FC/APC
Part Number : SCL0-ECL-1560-B-A81-L05-M0-SA |
Unit Price : USD [Please inquire] |
Lead time : [Please inquire] |
Inventory quantity : [Please inquire] |
Stock NO. : |
Email Us Request for Quotation |
Using self-designed and produced external cavity chips, the laser achieves stable output with narrow linewidth, high power and low noise through hybrid integration, which is suitable for the field of highly integrated coherent detection. It has low phase noise, low frequency noise, and the integrated line width can reach below 100kHz. It has small design size, stable performance and excellent vibration characteristics.
Basic indicators:
Output light characteristics | Parameter | Unit |
Output optical power | ≥ 10,20 | mW |
Integral linewidth | ≤100(note1) | kHz |
intrinsic linewidth | <100 | Hz |
Working wavelength | Reference:Table 2 | nm |
frequency stability | Typical <10-8 (2MHz) | @100s |
Relative intensity noise | ≤-150 | dBc/Hz |
Operating temperature | -10~60 | ℃ |
Light isolation | ≥40 | dB |
Electrical properties | parameter | unit |
Supply voltage | 5-6 | V |
Normal working current | 500(note2) | mA |
Module starting current | 1500(note3) | mA |
Note 1: The phase noise method is used to test, which is similar to the Lorentz linewidth of the simple test using the delayed self-difference beat method.
Note 2: Typical values are related to the external operating temperature.
Note 3: The current value of the module under the TEC high-current working state during startup. To ensure normal startup, the power supply is usually required to provide a current of 2A.
Spectral analysis
Linewidth test
Linewidth Measurement(CW,13.5kHZ@25deg)